電纜橋架廠家的劃線定位要注意什么?
防火電纜橋架廠家的劃線定位
Marking and positioning of fire-resistant cable tray manufacturers
當(dāng)蓋板掩蓋時(shí),線槽接口應(yīng)與插槽蓋接口移位,防止兩個(gè)接口堆疊,然后可以進(jìn)步整個(gè)線槽的剛性。缺少陽(yáng)角關(guān)節(jié)時(shí)的施工方法。剛性角接頭用于線槽作為90°彎曲的線槽。在制作時(shí),插槽側(cè)高度尺度高度尺度,在一條線槽的結(jié)束底部,并且用切開(kāi)切出DIPK。在另一條線槽端,每次切開(kāi)沿凹槽的底表面和兩個(gè)槽的周圍面的刀,切開(kāi)深度是凹槽側(cè)的高尺度,然后切開(kāi)彎曲槽的底部,然后彎曲部分聯(lián)接到前部槽口用鉚釘固定。相應(yīng)的槽蓋彎曲,并且可以發(fā)現(xiàn)線槽由90°彎曲制成。
When the cover plate is covered, the slot interface should be shifted from the slot cover interface to prevent the two interfaces from stacking, and then the rigidity of the entire slot can be improved. The construction method when there is a lack of male corner joints. Rigid corner joints are used for trunking as 90 ° curved trunking. During production, the height scale of the slot side is at the bottom of the end of a wire slot, and DIPK is cut out by cutting. At the other end of the wire groove, cut the bottom surface of the groove and the surrounding surfaces of both grooves with a knife each time, with a cutting depth of the high scale of the groove side. Then cut the bottom of the curved groove, and the curved part is connected to the front slot and fixed with rivets. The corresponding slot cover is bent, and it can be observed that the cable tray is made of a 90 ° bend.
聯(lián)接聯(lián)接頭時(shí)的施工方法。內(nèi)部(外部)聯(lián)接頭附件是在相同規(guī)格線之間運(yùn)用封閉。當(dāng)結(jié)構(gòu)可以選用約15-20厘米的相同尺度的截面,而不是聯(lián)接頭部成品?!奥?lián)接器”一般嵌入線槽(內(nèi)聯(lián)接器)的內(nèi)部,以堅(jiān)持整個(gè)線路槽的外觀。將“關(guān)節(jié)”鉆頭更好,用自攻螺釘或芯鋁釘固定“聯(lián)接器”。
Construction methods for connecting joints. Internal (external) connector accessories are enclosed between lines of the same specification. When the structure can be selected with a cross-section of about 15-20 centimeters of the same scale, instead of connecting the head products. The "coupler" is generally embedded inside the conduit (inline connector) to maintain the appearance of the entire conduit. Better use a "joint" drill bit and secure the "coupler" with self tapping screws or core aluminum nails.
電纜橋架時(shí)的施工方法。當(dāng)線槽在90°內(nèi)彎曲時(shí)運(yùn)用曲線角接頭,這可以通過(guò)切開(kāi)罐自身來(lái)抵達(dá)意圖。這種做法如下:在線槽的雙面槽側(cè),它在內(nèi)彎的周圍面上交叉。運(yùn)用鐵切成兩個(gè)45°的空隙,然后線槽減小到空隙,使得凹槽的周圍面向外,然后鉚接固定固定,以便制作簡(jiǎn)單,凹槽相應(yīng)部分的蓋可以彎曲,并且可以在蓋子的兩頭切開(kāi)兩頭,并且可以制作槽蓋。
Construction methods for cable trays. When the trunking bends within 90 degrees, use curved corner joints, which can be achieved by cutting open the can itself. This approach is as follows: on the double-sided groove side of the online slot, it intersects on the surrounding surface of the inner bend. Cut iron into two 45 ° gaps, then reduce the wire groove to the gap so that the groove faces outward, and then rivet and fix it for easy production. The cover of the corresponding part of the groove can be bent, and both ends of the cover can be cut open, and the groove cover can be made.